Rohde & Schwarz Handbuch-Download
| Beschreibung | Download | |||
|---|---|---|---|---|
| Manuale | ||||
| Audioanalysator | ||||
| UPP | Audioanalyzer Quick-Start-Manual | ![]() | Manual pdf 4 MB Getting Started | |
| UPP | Audioanalyzer Manual | ![]() | Manual pdf 11 MB Manual | |
| Oszilloskope | ||||
| RTE1000 | 2-/4-Kanal, 200 MHz bis 2 GHz | ![]() | Manual pdf 8 MB Getting Started | |
| MXO5C | 4-Kanal, 350 MHz - 2 GHz & 8-Kanal, 100 MHz - 2 GHz Getting started Manual | ![]() | Manual pdf 5 MB | |
| MXO5C | 4-Kanal, 350 MHz - 2 GHz & 8-Kanal, 100 MHz - 2 GHz Manual | ![]() | Manual pdf 63 MB | |
| MXO5 | 4-Kanal, 350 MHz - 2 GHz & 8-Kanal, 100 MHz - 2 GHz Getting started Manual | ![]() | Manual pdf 1 MB |
|
| MXO4 | 4-Kanal, 200 MHz - 1 GHz Kompl. Manual | ![]() | Manual pdf 18 MB |
|
| MXO4 | 4-Kanal, 200 MHz - 1 GHz Getting started | ![]() | Manual pdf 1 MB |
|
| MXO3 | 4-/8-Kanal, 100 MHz - 1 GHz Manual (MXO34, MXO38) | ![]() | Manual pdf 40 MB |
|
| RTA4000 | 4-Kanal, 200 MHz - 1 GHz | ![]() | Manual pdf 9 MB |
|
| RTM3000 | 2-/4- Kanal, 100 MHz - 1 GHz Vers. 03 2018 deutsch | ![]() | Manual DE pdf 16 MB |
|
| RTM3000 | 2-/4- Kanal, 100 MHz - 1 GHz Vers. 08 2021 englisch | ![]() | Manual EN pdf 10 MB |
|
| RTB22/ RTB24 | 2-/4- Kanal, 70 MHz - 300 MHz | ![]() | Manual pdf 14 MB |
|
| RTB2000 | 2-/4- Kanal, 70 MHz - 300 MHz | ![]() | Manual Vers.12 DE Vers.10 EN |
|
| RTB2000 | Darstellung des Oszilloskop-Bildschirms auf einem PC via LAN | ![]() | Manual pdf 3 MB |
|
| RTC1000 | 2-Kanal, 50 - 300 MHz | ![]() | Manual pdf 13 MB |
|
| RTH | Scope Rider | ![]() | Manual pdf 8 MB |
|
| RTM2000 | 2-/4-Kanal - Gerät ist abgekündigt | ![]() | Manual pdf 16 MB |
|
| HMO3000 Serie | HMO3002 Serie 2-Kanal Mixed-Signal-Oszilloskope HMO3004 Serie 4-Kanal Mixed-Signal-Oszilloskope HMO3032, HMO3034: 300 MHz HMO3042, HMO3044: 400 MHz HMO3052, HMO3054: 500 MHz | Manual pdf 11 MB |
||
| HMO Compact Serie | 2- oder 4-Kanal Mixed Signal Oszilloskope HMO722, HMO724: 70 MHz HMO1022, HMO1024: 100 MHz HMO1522, HMO1524: 150 MHz HMO2022, HMO2024: 200 MHz | Manual pdf 11 MB |
||
| Analysatoren | ||||
| FPC1000 FPC1500 | Spektrumanalysator 1GHz - 3 GHz (FPC1500 mit Trackinggenerator) | Manual pdf 4 MB |
||
| FSC3 FSC6 | Spektrumanalysator 3/ 6 GHz | Manual pdf 4 MB |
||
| FSH4/ 8/ 13/ 20 | Handheld-Spektrumanalysator 4/ 8/ 13/ 20 GHz | Manual pdf 7 MB |
||
| FPH | Spectrum Rider Handheld Spektrumanalysator Getting Started Manual | Manual pdf 2 MB |
||
| FPH | Spectrum Rider Handheld Spektrumanalysator Manual | Manual pdf 6 MB |
||
| FSL3 / FSL6 | Spektrumanalysator | ![]() | Manual pdf 6 MB |
|
| FPL1000 | Spektrumanalysator Getting Started Manual | ![]() | Manual pdf 3 MB |
|
| FPL1000 | Spektrumanalysator kpl. Manual | ![]() | Manual pdf 16 MB |
|
| FPL1-K40 Option | FPL1-K40 Phase noise measurement | ![]() | Manual pdf 9 MB |
|
| HMS-X | Spektrumanalysator | ![]() | Manual pdf 5 MB |
|
| ZVH | Antennen- und Kabelanalysator | ![]() | Manual pdf 2 MB |
|
| ZVH | Remote Control via LAN or USB Software Manual | ![]() | Flyer pdf 3 MB |
|
| EPL1000 | EMI-Testreceiver Manual | ![]() | Manual pdf 17 MB |
|
| ESL | EMI-Testreceiver | ![]() | Manual pdf 6 MB |
|
| Vector Netzwerk Analysatoren | ||||
| ZNL / ZNLE | Vektor Netzwerkanalysatoren | Manual pdf 15 MB |
||
| ZNL3-B1 | Option "Spektrum Analysator Mode" für ZNL3 | Manual pdf 10 MB |
||
| ZND | Vector Netzwerkanalysator Manual | ![]() | Manual pdf 16 MB |
|
| ZND | Vector Netzwerkanalysator Manual -Getting Started- | ![]() | Manual pdf 5 MB |
|
| ZNH | Vector Netzwerkanalysator Getting Started Manual | ![]() | Manual pdf 1 MB |
|
| ZNH | Vector Netzwerkanalysator Manual | ![]() | Manual pdf 4 MB |
|
| Kabel- und Antennenanalysator | ||||
| ZPH | Cable Rider Handheld Kabel- und Antennenanalysator | ![]() | Manual pdf 9 MB |
|
| ZPH ZND | Health Guide - For vector network analyzers gives advice to prevent electrical and mechanical damage | ![]() | Flyer pdf 1 MB |
|
| Multimeter | ||||
| HMC8012 | Multimeter | ![]() | Manual pdf 3 MB |
|
| Leistungsmessgeräte / Leistungsanalysatoren | ||||
| NPA101/ NPA501/ NPA701 | Leistungsanalysator 50 μW bis 12 kW, einphasig | Manual pdf 7 MB |
||
| HMC8015 | Leistungsanalysator 50 μW bis 12 kW, einphasig | Manual pdf 4 MB |
||
| NRX | Powermeter -Getting-Started-Manual | Manual pdf 4 MB |
||
| NRX | Powermeter -Manual | Manual pdf 30 MB |
||
| NRQ6 | Leistungsmesskopf Manual | ![]() | Manual pdf 15 MB |
|
| NRQ6 | Leistungsmesskopf Getting Started Manual | ![]() | Manual pdf 9 MB |
|
| NRT2 | NRT2 Power-Reflection-Meter Manual | ![]() | Manual pdf 3 MB |
|
| Leistungsmessköpfe | ||||
| NRPxxS(N) Power Sensoren | Three-Path Power Sensors Manual | ![]() | Manual pdf 6 MB |
|
| NRPxx Power Sensoren | NRP Power Sensoren Getting Started Manual NRPxxA, NRPxxS, NRP18S-xx, NRPxxT, NRPxxTWG | ![]() | Manual pdf 3 MB |
|
| NRP-Z Power Sensoren | NRP-Z Power Sensoren Getting Started Manual | ![]() | Manual pdf 1 MB |
|
| Netzgeräte | ||||
| HMP2000 / HMP4000 | 2-4 fach Netzgeräte | Manual pdf 5 MB |
||
| HMC804x | 1-3-Kanal Netzgerät, 0...32 V/ 3 A, 100 W | Manual pdf 3 MB |
||
| NGA100 | Netzgerät Manual | Manual pdf 5 MB |
||
| NGC101/ NGC102/NGC103 | Labornetzgeräte 1-/ 2-/ 3-Kanal | Manual pdf 7 MB |
||
| NGE102B / NGE103B | 2-Kanal, 0 bis 32 V / 3 A, max. 66 W 3-Kanal, 0 bis 32 V / 3 A, max. 99 W | Manual pdf 5 MB |
||
| NGL200 / NGM200 | Netzgerät | Quick Start Manual pdf 4 MB |
||
| NGL200 / NGM200 | Netzgerät | Manual pdf 7 MB |
||
| NGP800 Serie | Netzgeräteserie mit 2-/ 4-Kanal Getting Started Manual | Manual pdf 3 MB |
||
| NGP800 Serie | Netzgeräteserie mit 2-/ 4-Kanal | Manual pdf 9 MB |
||
| NGU201 NGU401 | NGU SMUs Getting Started Manual | Manual pdf 3 MB |
||
| NGU201 NGU401 | NGU SMUs kpl. Manual | Manual pdf 3 MB |
||
| HM7042 | 3-fach Netzgerät | ![]() | Manual pdf 4 MB |
|
| HM8143 | 3-fach Netzgerät, Arbitrary | Manual pdf 2 MB |
||
| Generatoren | ||||
| HMF2525 / HMF2550 | 25/50 MHz Arbitrary-Generator | Manual pdf 3 MB |
||
| HMF2525 / HMF2550 | SCPI-Programmers Guide | Manual pdf 1 MB |
||
| SMC100A | Signalgenerator | ![]() | Manual pdf 5 MB |
|
| SMB100A | RF-Generator | ![]() | Manual pdf 5 MB |
|
| SMB100B | Generator | ![]() | Manual pdf 13MB |
|
| SMBV100B | Vector Signal Generator Quick started Manual | ![]() | Manual pdf 5 MB |
|
| SMBV100B | Vector Signal Generator inkl. Options | ![]() | Manual pdf 22 MB |
|
| SMCV100B | Vector Signal Generator | ![]() | Manual pdf 10 MB |
|
| all Generators | Health Guide for signal generators gives advice to prevent electrical and mechanical damage. | ![]() | Note pdf 2 MB |
|
| LCR-Meter | ||||
| LCX100 / LCX200 | LCR-Messbrücke Quick started Manual | Manual pdf 1 MB |
||
| LCX100 / LCX200 | LCR-Messbrücke kpl. Manual | Manual pdf 10 MB |
||
| HM8118 | LCR-Messbrücke, 20 Hz ... 200 kHz | Manual pdf 3 MB |
||
| Frequenzzähler | ||||
| HM8123 | Frequenzzähler | ![]() | Manual pdf 2 MB |
|
| Netznachbildung | ||||
| AMN6500 | Zweileiter Netznachbildung | ![]() | Manual pdf 4 MB |
|
| ENV216 | Zweileiter Netznachbildung | ![]() | Manual pdf 4 MB |
|
| ENV432 | Vierleiter Netznachbildung | ![]() | Manual pdf 1 MB |
|
| ENV4200 | Vierleiter Netznachbildung | ![]() | Manual pdf 2 MB |
|
| ESH3-Z6 | Netznachbildung | ![]() | Manual pdf 3 MB |
|
| HM6050 | Zweileiter Netznachbildung | ![]() | Manual pdf 1 MB |
|
| Zubehör | ||||
| Differenz-Tastköpfe | ||||
| RT-ZD01 | 100 MHz 100:1/1000:1 | ![]() | Manual pdf 6 MB |
|
| RT-ZD02 | 200 MHz, 10:1 | ![]() | Manual pdf 1 MB |
|
| RT-ZD002 RT-ZD003 | 25 MHz, 10:1 / 100:1 25 MHz, 20:1 / 200:1 | ![]() | Manual pdf 1 MB |
|
| RT-ZD08 | 800 MHz, 10:1 | ![]() | Manual pdf 1 MB |
|
| RT-ZD10 RT-ZD20 RT-ZD30 RT-ZA15 | 1,0 GHz, 1 MΩ, 1,5 GHz, 1 MΩ, 3,0 GHz, 1 MΩ, (ZA15 external Attenuator) | ![]() | Manual pdf 4 MB |
|
| RT-ZD40 | 4,5 GHz, 1 MΩ | ![]() | Manual pdf 5 MB |
|
| RT-ZHD07 RT-ZHD15 RT-ZHD16 RT-ZHD60 | 200 MHz, 25:1/ 250:1 100 MHz, 50:1/ 500:1 200 MHz, 50:1/ 500:1 100 MHz, 100:1/ 1000:1 | ![]() | Manual pdf 5 MB |
|
| Optical-Isolated Probing System | ||||
| RT-ZISO | Optical Isolated Probing System | ![]() | Manual pdf 6 MB |
|
| Standard-Tastköpfe | ||||
| RT-ZP1X | 38 MHz passiver Tastkopf, 2,5mm , 1:1 | ![]() | Manual pdf 1 MB |
|
| RT-ZP03S | 300 MHz passiver Tastkopf, 10:1 | ![]() | Manual pdf 1 MB |
|
| RT-ZP05S | 500 MHz passiver Tastkopf, 10:1 | ![]() | Manual pdf 2 MB |
|
| RT-ZI10 | 500 MHz passiver Tastkopf, 10:1 | ![]() | Manual pdf 1 MB |
|
| RT-ZI11 | 500 MHz Isolierter passiver Tastkopf, 100:1 max1000V CAT III (600V CAT IV) | Manual pdf 1 MB |
||
| Hochspannungs-Tastköpfe | ||||
| RT-ZH03 | 250 MHz passiver Hochspannungs-Tastkopf 5mm, 100:1 | ![]() | Manual pdf 1 MB |
|
| RT-ZH10 | 400 MHz, passiver Hochspannungstastkopf 100:1 | ![]() | Manual pdf 1 MB |
|
| RT-ZH11 | 400 MHz passiver Hochspannungs-Tastkopf 1000:1 | ![]() | Manual pdf 1 MB |
|
| Power-Rail-Tastköpfe | ||||
| RT-ZPR20 / RT-ZPR40 | Power-Rail Tastkopf 1:1 Teilungsverhältnis, 2 GHz/ 4GHz Bandbreite (Link: Anwendungsbeispiel Power Integrity Messung) | ![]() | Manual pdf 23 MB |
|
| Aktive Breitband Tastköpfe | ||||
| RT-ZS10, RT-ZS10E, RT-ZS20, RT-ZS30 | aktive Breitband Tastköpfe | ![]() | Manual pdf 4 MB |
|
| Modulare Tastköpfe | ||||
| RT-ZM15, RT-ZM30, RT-ZM60, RT-ZM90, RT-ZM130, RT-ZM160 | Modulare Breitbandtastköpfe | ![]() | Manual pdf 4 MB |
|
| Mehrkanal Leistungstastköpfe | ||||
| RT-ZVC | Mehrkanal Leistungstastköpfe | ![]() | Manual pdf 5 MB |
|
| Stromzangen | ||||
| RT-ZC02 RT-ZC03 | 20 kHz, AC/DC, 200A/ 1000A, BNC, Batteriebetrieb 100 kHz, AC/DC, 30A, BNC, Batteriebetrieb | ![]() | Manual |
|
| RT-ZC05B | 2 MHz, AC/DC, 0.01 V/A, 500 A (RMS), R&S probe interface | ![]() | Manual |
|
| RT-ZC10 | 10 MHz, AC/DC, 0.01 V/A, 150 A (RMS) , BNC interface | ![]() | Manual |
|
| RT-ZC10B | 10 MHz, AC/DC, 0.01 V/A, 150 A (RMS), R&S probe interface | ![]() | Manual |
|
| RT-ZC15B | 50 MHz, AC/DC, 0.1 V/A, 30 A (RMS), R&S probe interface | ![]() | Manual |
|
| RT-ZC20 | 100 MHz, AC/DC, 0.1 V/A, 30 A (RMS), BNC interface | ![]() | Manual |
|
| RT-ZC20B | 100 MHz, AC/DC, 0.1 V/A, 30 A (RMS), R&S probe interface | ![]() | Manual |
|
| RT-ZC30 | 120 MHz, AC/DC, 1 V/A, 5 A (RMS), BNC interface | ![]() | Manual |
|
| RT-ZC31 | 120 MHz, AC/DC, 0,1 V/A, 30 A und 1 V/A, 5 A und 10 V/A 0,5A (RMS), BNC interface. | ![]() | Manual |
|
| HZC50 HZC51 | 100 kHz, AC/DC, 30A, 4mm Anschlüsse 20 kHz, AC/DC, 1000A, 4mm Anschlüsse | ![]() | folgt in Kürze | |
| EZ-17 | Stromzange für Emissionsmessungen | ![]() | Manual |
|
| Adapter / probe extender / Messgeräte Zubehör | ||||
| RT-ZA50 | Oszilloskop Tastkopf Erweiterungssatz - Adapter R&S Probe Interface auf 2,92 mm/3,5 mm/SMA, inkl. USB-C Port | ![]() | Manual |
|
| RT-ZA51 | Oszilloskop Tastkopf Erweiterungssatz - Adapter 2,92 mm/3,5 mm/SMA auf R&S Probe Interface, inkl. USB-C Port | ![]() | Manual |
|
| RT-Z2T | Tastkopfschnittstellen-Adapter für Verwendung von verschiedenen Tektronix-Tastköpfen mit TekProbe Level-II-Schnittstelle an R&S Oszilloskopen der Serien RTM3000, RTA4000, RTE1000, RTO2000 | ![]() | Manual pdf 1 MB |
|
| Software | ||||
| ELEKTRA | EMI Testsoftware | ![]() | Manual pdf 5 MB |
|
| R&S License Manager | Configuration and operation of the Rohde & Schwarz License Server | ![]() | Manual pdf 2 MB |
|
| CDS Campus Dashboard | Lab Configuration Software | ![]() | Manual pdf 2 MB |
|
| HMExplorer | R&S (HAMEG) Software Manual Software für verschiedene Messgeräte wie Netzgeräte NGL-, NGM-, NGP-, NGE-, HMP-, NGU, NGA, HMC804x-Serien, Generatoren HMF-Serie, Leistungsanalysator HMC8015, Multimeter HMC8012, Spektrumanalysatoren HMS-x, HMS10x0-HMS30x0 div. ältere HAMEG Oszilloskope | ![]() | Manual pdf 2 MB |
|
| EMV-Messtechnik | ||||
| MDS21 | Absorptions-Messwandlerzange 30 MHz - 1 GHz zur Funkstörleistungsmessung auf Leitungen nach CISPR und Messung der Schirmdämpfung von Leitungen nach IEC 62153-4 und EN 50083-2 | ![]() | Manual pdf 1 MB |
|
| HZ540 | Nahfeld-Sondensatz | ![]() | Manual pdf 1 MB |
|
| Antennen | ||||
| Test-Fixtures | ||||
| RT-ZF20 | Power Deskew and Calibration Test Fixture - Für Power Integrity Messungen ist ein genauer Abgleich zwischen Spannungs- und Stromsignal essentiell. Die Deskew Fixture erlaubt die Messung von Laufzeitunterschieden, die dann im Oszilloskop korrigiert werden können (z.B. bei RTE1000, RTM3000, RTA4000) | ![]() | Manual pdf 1 MB |
|
| 19" Rackeinbau Sätze | ||||
| HZ42, HZ43, HZ45, HZ46, HZO91, HZP91 | 19" Rackeinbausätze, Montageskizzen | ![]() | Manual pdf 2 MB |
|
| HZN96 | 19" Rackeinbausatz 2HE für NGL200-, NGM200-Netzgeräteserien, SMCVB100B Signal Generator Manual Montageskizzen | ![]() | Manual pdf 2 MB |
|
| HZC95 | 19" Rackeinbausätze, Montageskizzen für HMC8012, HMC804x | ![]() | Manual pdf 2 MB |
|
| ZZA-GE23 | 19" Rackeinbausätze, Montageskizzen für NGP800 Netzgeräte und CCX LCR-Meter | ![]() | Manual pdf 2 MB |
|
| Vergleich Mitbewerb | ||||
| Firmware | ||||
| Gerätetreiber | ||||
| Software | ||||











